<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"><channel><title>Carl Zeiss Meditec recalls | PlainRecords</title><link>https://plainrecords.com/brand/carl-zeiss-meditec/</link><description>New recalls of Carl Zeiss Meditec from FDA, CPSC and NHTSA records.</description><language>en-us</language><item><title>Zeiss Intrabeam Spherical Applicator 1.5 cm REF:304534-6000-557</title><link>https://plainrecords.com/recall/device/z-2649-2026/</link><guid>https://plainrecords.com/recall/device/z-2649-2026/</guid><pubDate>Wed, 08 Jul 2026 00:00:00 +0000</pubDate><description>Spherical applicators (radiation therapy accessory) failed to meet manufacturing specifications.</description></item><item><title>ZEISS miLOOP Lens Fragmentation Device REF 303071-9090-000…</title><link>https://plainrecords.com/recall/device/z-1007-2022/</link><guid>https://plainrecords.com/recall/device/z-1007-2022/</guid><pubDate>Wed, 04 May 2022 00:00:00 +0000</pubDate><description>High friction of the slider can cause the device to stick, or not move as intended.</description></item><item><title>Cirrus Hd-Oct…</title><link>https://plainrecords.com/recall/device/z-0723-2022/</link><guid>https://plainrecords.com/recall/device/z-0723-2022/</guid><pubDate>Wed, 16 Mar 2022 00:00:00 +0000</pubDate><description>Optic nerve head angiography scan to be turned off due to its distribution without pre-market clearance.</description></item><item><title>Chassis Label…</title><link>https://plainrecords.com/recall/device/z-2227-2021/</link><guid>https://plainrecords.com/recall/device/z-2227-2021/</guid><pubDate>Wed, 18 Aug 2021 00:00:00 +0000</pubDate><description>Due to failure to acquire pre-market clearance for its high resolution tomographic/biomicroscope imaging device (Model 6000) prior to commercializing the device.</description></item><item><title>IOLMaster 700</title><link>https://plainrecords.com/recall/device/z-1133-2021/</link><guid>https://plainrecords.com/recall/device/z-1133-2021/</guid><pubDate>Wed, 24 Feb 2021 00:00:00 +0000</pubDate><description>When using software 1.90.2.09 or 1.90.8.06 and using modality worklist functionality for patient data transfer, the selection of the patient in the patient list may not match the patient information displayed on the right side of the screen</description></item><item><title>Carl Zeiss Meditec Ag VISULENS 550 REF 2268-038… and 1 more product</title><link>https://plainrecords.com/recall/device/z-0613-2021/</link><guid>https://plainrecords.com/recall/device/z-0613-2021/</guid><pubDate>Wed, 23 Dec 2020 00:00:00 +0000</pubDate><description>Due to the incorrect DC/DC converter being assembled onto the communication board. As a result the effectiveness of the communication board cannot be guaranteed in that the safety function of the board would be insufficient resulting in an increased leakage of current and potentially cause electrical shocks to the user.</description></item><item><title>The PLEX Elite 9000…</title><link>https://plainrecords.com/recall/device/z-0770-2020/</link><guid>https://plainrecords.com/recall/device/z-0770-2020/</guid><pubDate>Wed, 08 Jan 2020 00:00:00 +0000</pubDate><description>Under certain fault conditions, the existing design may expose the operator to a hazardous voltage when contacting the metal enclosure (including mounting screws) around the up/down switch.</description></item><item><title>VisuMax Software Version 2.10.13 with activated Software-Module ReLEx (SMILE) option used in conjunction with…</title><link>https://plainrecords.com/recall/device/z-0680-2020/</link><guid>https://plainrecords.com/recall/device/z-0680-2020/</guid><pubDate>Wed, 25 Dec 2019 00:00:00 +0000</pubDate><description>VisuMax devices with software version 2.10.13 and activated SW-Module ReLEx (SMILE) option may experience a software issue. In case of a suction loss during treatment the software allows the user to choose the option immediate restart or restart treatment. Suction loss can occur in phase 1 through phase 5. The software defect refers to Phase 2 (between 10% and 100% of lower lenticule cut) only.…</description></item><item><title>Carl Zeiss Meditec AG…</title><link>https://plainrecords.com/recall/device/z-0108-2019/</link><guid>https://plainrecords.com/recall/device/z-0108-2019/</guid><pubDate>Wed, 24 Oct 2018 00:00:00 +0000</pubDate><description>Calibration setting was incorrectly entered during manufacturing causing the optical coherence tomography (OCT) to obtain the incorrect two-dimensional images of ocular structures of the anterior and posterior segments of the eye.</description></item><item><title>Carl Zeiss INTRABEAM PRS 500…</title><link>https://plainrecords.com/recall/device/z-0001-2018/</link><guid>https://plainrecords.com/recall/device/z-0001-2018/</guid><pubDate>Wed, 11 Oct 2017 00:00:00 +0000</pubDate><description>The device had an incorrect printed calibration value on the calibration certificate.</description></item><item><title>IOL Master 5.5: Software versions 7.5 and 7.7… and 1 more product</title><link>https://plainrecords.com/recall/device/z-0357-2016/</link><guid>https://plainrecords.com/recall/device/z-0357-2016/</guid><pubDate>Wed, 09 Dec 2015 00:00:00 +0000</pubDate><description>IOL Master software versions 7.5 and 7.7 calculation printouts and exported reports can contain the wrong IOL power data.</description></item><item><title>FORUM Archive and Viewer…</title><link>https://plainrecords.com/recall/device/z-1049-2015/</link><guid>https://plainrecords.com/recall/device/z-1049-2015/</guid><pubDate>Wed, 11 Feb 2015 00:00:00 +0000</pubDate><description>Software defect in the FORUM Viewer versions 3.1 and 3.2 which may lead to misinterpretation of the optical coherence tomography (OCT) data.</description></item><item><title>Treatment packs used on the VisuMax Laser Keratome…</title><link>https://plainrecords.com/recall/device/z-1153-2014/</link><guid>https://plainrecords.com/recall/device/z-1153-2014/</guid><pubDate>Wed, 19 Mar 2014 00:00:00 +0000</pubDate><description>Carl Zeiss Treatment pack, lot number M 130010, size M, may actually contain size S.</description></item><item><title>Zeiss brand IOLMaster… and 1 more product</title><link>https://plainrecords.com/recall/device/z-0333-2014/</link><guid>https://plainrecords.com/recall/device/z-0333-2014/</guid><pubDate>Wed, 27 Nov 2013 00:00:00 +0000</pubDate><description>The user database delivered for download contained an erroneous value. Specifically the &quot;aO&quot; constant of the lens AMO Sensar AR40E is listed as &quot;0.0&quot; in the internal lens database of the IOLMaster. The correct value is -2.420. This could lead to the implantation of lens with a wrong diopter value.</description></item><item><title>Zeiss brand OPMI Pentero C…</title><link>https://plainrecords.com/recall/device/z-1440-2013/</link><guid>https://plainrecords.com/recall/device/z-1440-2013/</guid><pubDate>Wed, 12 Jun 2013 00:00:00 +0000</pubDate><description>Carl Zeiss Meditec is conducting a field corrective action for its OPMI Pentero C surgical microscope system. During a routine inspection, one microscope installation was found to have 3 (three) broken screws out of 6 (six) in the lower section of the ceiling mount.</description></item><item><title>INTRABEAM Balloon Applicator Set… and 2 more products</title><link>https://plainrecords.com/recall/device/z-0404-2013/</link><guid>https://plainrecords.com/recall/device/z-0404-2013/</guid><pubDate>Wed, 28 Nov 2012 00:00:00 +0000</pubDate><description>A manufacturing defect has been identified which could results in the small tube becoming dislodged between the luer fitting and the check valve.</description></item><item><title>OPMI VARIO 700 Surgical Microscope…</title><link>https://plainrecords.com/recall/device/z-0105-2012/</link><guid>https://plainrecords.com/recall/device/z-0105-2012/</guid><pubDate>Mon, 24 Oct 2011 00:00:00 +0000</pubDate><description>An incorrect nut and bolt set was used in the axis three (3) spring assembly of the OPMI VARIO 700 surgical microscope distributed to three US locations.</description></item><item><title>OPMI Pentero…</title><link>https://plainrecords.com/recall/device/z-3275-2011/</link><guid>https://plainrecords.com/recall/device/z-3275-2011/</guid><pubDate>Fri, 23 Sep 2011 00:00:00 +0000</pubDate><description>Some third party surgical drapes have optically active protective lenses that could affect the ZEISS surgical microscope position information that is passed on to third party navigation systems.</description></item><item><title>INTRABEAM Shielding Material Flat 20 x 20 cm…</title><link>https://plainrecords.com/recall/device/z-2989-2011/</link><guid>https://plainrecords.com/recall/device/z-2989-2011/</guid><pubDate>Wed, 10 Aug 2011 00:00:00 +0000</pubDate><description>Carl Zeiss Meditec received a report that the INTRABEAM 20 x 20 cm sterile shield&#x27;s packaging looked wet inside. Investigation found the substance to be Triethylene Glycol,</description></item><item><title>Cirrus HD-OCT Model 400 instruments… and 1 more product</title><link>https://plainrecords.com/recall/device/z-2126-2011/</link><guid>https://plainrecords.com/recall/device/z-2126-2011/</guid><pubDate>Mon, 02 May 2011 00:00:00 +0000</pubDate><description>A software defect exists in versions 5.0.0 and 5.1.0 where when following a specific workflow, exam data may be saved under the name of the first patient</description></item><item><title>VISU 200 on S8 Floor Stand…</title><link>https://plainrecords.com/recall/device/z-0904-2011/</link><guid>https://plainrecords.com/recall/device/z-0904-2011/</guid><pubDate>Fri, 14 Jan 2011 00:00:00 +0000</pubDate><description>Potential Retina Damage-- An error in the user manual may result in misapplied filter and injury during treatment.</description></item><item><title>Stratus OCT Model 3000 instruments distributed with version 6.0.0 software…</title><link>https://plainrecords.com/recall/device/z-2048-2009/</link><guid>https://plainrecords.com/recall/device/z-2048-2009/</guid><pubDate>Thu, 03 Sep 2009 00:00:00 +0000</pubDate><description>Mis-labeled image. A bug in version 6.0.0 software and 6.0.0 software kit used with Stratus OCT Model 3000 can produce a report that incorrectly labels OD or OS.</description></item></channel></rss>